A2
Light type OTA measurement system
-
Minimized space-saving design
-
Plug and play, no need for EMC extra construction
-
Simplified testing steps and lessen measurement time while maintaining stable and accurate data
System
Operating frequency |
0.68-3.8GHz |
Dimension (L/W/H) |
1.0 x 0.8 x 2.1m |
Maximum tested object |
6.5" hand-held device |
Measurement distance |
1.0m |
Shielding effect |
0.68-3.8GHz > 80dB
|
Quiet zone size |
- |
Quiet zone characteristics |
- |
Absorber |
Emerson & Cuming non-toxic proof (RoHS and REACH) |
Path loss Active Typically |
45dB @ 3.8 GHz |
System stability |
TIS SD *1<1.5 dB TRP SD < 1dB |
Antenna test time |
- |
TRP / TIS test time |
15 minutes (TRP 3 channels + TIS 3 channels) |
Dissipated power |
1.0 kW |
Input power |
110 VAC/ 220 VAC |
Software |
- |
Shielding chamber
Chamber gross weight |
350 Kg |
Shielding door dimension (W/H) |
0.5 x 0.5 m |
Shielding door type |
Electric locking sector door |
Shielding steel sheet thickness |
2 mm |
Shielding vent size |
- |
Light source |
- |
Laser position monitoring |
- |
Power source filter |
24 VDC/10 A |
Internal power source |
- |
Signal filter |
- |
Interface connector |
N- Type |
3D Turntable
Turntable diameter | 0.5m |
Turntable load |
< 1 Kg |
Turntable type |
3D |
Turntable accuracy |
1 degree |
Turntable resolution |
0.1 degree |
Max. turntable speed |
Phi 10 RPM, Theta 12 RPM |
Input power |
110 VAC 60 Hz |
Control method |
- |
Phi axis removal/moving |
- |
Standard fixtures |
6.5" hand-held device fixtures |
Optional fixtures |
- |
Measurement Antenna
Operation Frequency | 0.65 – 6.0GHz |
Polarization |
Circular polarization cone spiral antenna |
Polarized Shielding |
20dB |
Antenna gain |
13dBi @ 6.0GHz20dB |
Connector type |
SMA (Female) |
Dimension (L/W/H) |
0.25 X 0.25 X 0.3m |
Weight |
1.0Kg |
Communication antenna |
- |
Microwave path assembly (including cable)
Operating frequency | 0.65 – 3.8GHz |
Active path loss*2 |
10dB @ 3.8GHz |
Path type / quantity |
- Purely active, measure with a combined testing instrument TRP and TIS - Do not support the spectrum analyzer |
Total number of instruments |
Supports a single combined testing instrument |
Control method |
- |
Input power |
- |
Option contents |
- |
Control unit
Control unit | Industrial Computer Windows operating system Microsoft spreadsheet (Excel) GPIB interface card |
Installation Requirements |
|
Working dimension (L/W/H) |
2.0 X 2.0 X 2.5m |
Equipment power requirement |
110/220VAC 50/60Hz 20Amp |